Professional RitmScenar

A pocket size electronic device using 3 AA batteries to stimulate the body's own pharmacy with harmless electric impulses via the skin. The brain mediates a bio-energy feedback by altering output every few milliseconds. The process initiates release of biological activators. Bio-feedback dynamics can induce remarkably rapid healing, allowing the body to heal itself. Meanwhile a wide variety of trained practitioners accumulated considerable experience, affirming the ability of scenar therapy to relieve and manage pain, thereby assisting the self-healing of hitherto intractable diseases, as well as common maladies of mind, body and spirit. Scenar can be used as stand-alone treatment or in harmony with other methods. The Ritmedic expert model is only to be used by scenar trained medical professionals.

Download here the 'Professional RitmScenar Productsheet (V 0.98)' in PDF format.

 

How it works

The basic mode of operation of Scenar devices is to deliver a "dosage" of electrical stimulation impulses to the body via an in-built and/or remote electrode in direct contact with the skin surface. These impulses have been tailored to mimic the electrical discharges of the nervous system, in order to elicit the organism's response with optimum efficiency and minimum disruption to cell function, depending upon the unique requirements of the presenting pain disease dynamics (or lack of the same). The action is aimed at both the "fast" pain blocking A-fibres and the "slow" pain producing and peptide generating C-fibres.


The signal stream, comprising waveform, signal strength (voltage and current) and frequency, can be varied in a number of ways, either by preselection by the operator or automatically by the control circuitry of the device. The "dosage" can be delivered automatically or overridden at the discretion of the operator, with guidance from visual indicators on numeri LED display.

The basic signal component is a bipolar pulse, consisting of a negative square-wave followed by a positive saw-tooth, starting and finishing at zero and lasting for a few microseconds. A number of these pulses may be packaged into a discrete burst (intensity) which itself may be repeated at a fixed default frequency. The individual pulses in these bursts (intensity more than 1) can themselves be spaced out (Z=10/close together, to 80/wide apart) to give a concentrated (deep) or diffuse (shallow) penetration, depending on local body density or depth of pain location.

Alternatively, a single pulse (intensity=1) may be preselected to a pulse repeat rate (PRP) over a set frequency range (say F=15-351 Hz). The signal may also be "modulated":
AM=Off, 1:1, 1:2, 1:3, 1:4, 1:5, BEE (amplitude modulation),
FM=Off, On, Swing (frequency modulation),
DMPF=Off, Sk1, Sk2, Sk3, Sk4, Var.
These "modulations" can either be applied individually or together.

There is also the possibility of automatically cycling both the repeat rate (PRP) over a set frequency range (FM -say from 30 to 180 Hz over 8 seconds) and the waveform damping factor (Dmpf =VAR). These cyclical modes can again be invoked either individually or together.

The purpose of all these variants is to make available to the operator a comprehensive arsenal with which to stimulate both acute and chronic conditions and prevent the body from adapting to the signal before there has been time to generate sufficient neuropeptides (endophins, etc.) to releave pain and create an enhanced environment for the organism to bring into play its own healing pharmacy to move towards homeostasis.

The power output can be set by the operator to be detectable but comfortable for the patient. It can also be adjusted during application should this be required. The maximum current output is 70 mA and the peak voltage is 180 V, derived from three internal AA batteries.

A further level of chaos is introduced by a random variation of the pulse amplitude from zero to the chosen comfort such that no two pulses are the same. This discourages adaptation in the organism. A feedback mechanism is provided by the constant monitoring of skin impedance, which will change with time and "dosage" delivered. Integration of these values permits calculation and display of rate of change (of current flow) and coefficient of waveform in relation to the starting point.

Scenar devices adhere to the concept that the maximum dosage required to effect change is the most appropriate. Ths is furthered by emphasis on increase of information rather than energy content, thus minimising the triggering of body retaliation and adaptation mechanisms.

Personal model